Core : 2 - 4
Cross-section : 1.5 mm2 - 6 mm2
Cables | Ship & yacht type cables
MYCY
Application:

These cables are mainly used in permanent installations such as e.g. lighting, control circuits, power cables in engine rooms, in ships. They are very resistant to all conditions in the marine environment such as dry, wet and oil. As they are screened, these cables can be use in comunication systems, radio and electronic equipments..

Cable design Tehnical data
Conductor : Plain or tinned Cu wires, flexible, IEC 228-5.
Insulation : PVC compound   
Lay-up : Cores laid up in layers of optimum pitch.
Inner Sheath : PVC compound.
Screen : Braid of plain Cu wires, %85 coverage.
Outer Sheath : Oil and flame resistant special PVC compound.
Outer Colour : Black
Standard : IEC 92-3, TS 2957
Insulation resistance : >20 Mohm.km
Rated voltage Uo/U : 0,6 / 6 kV
Test voltage (AC 50 Hz) : 4000 V
Temperature range : -40 °C +70 °C
Min. Bending radius : 10 x Cable diameter
Flame Retardant Test : IEC 332.1