Core : 2-4
Cross-section : 1.5 mm2 - 6 mm2
Cables | Ship & yacht type cables
MYY
Application:

These cables are mainly used in permanent installations such as power, lighting, controll circuits, in ships. They are very resistant to all conditions in the marine environment such as dry, wet and oil. However, as they are unscreened they are not suitable to be installed in closed areas of antenna and radio leads.

Cable design Tehnical data
Conductor : Plain or tinned Cu wires, flexible, IEC 228-5.
Insulation : PVC compound   
Lay-up : Cores laid up in layers of optimum pitch.
Inner Sheath : PVC compound.
Outer Sheath : Oil and flame resistant special PVC compound.
Outer Colour : Black
Standard : IEC 92-3, TS 2957
Insulation resistance : >20 Mohm.km
Rated voltage Uo/U : 0,6 / 6 kV
Test voltage (AC 50 Hz) : 4000 V
Temperature range : -40 °C +70 °C
Min. Bending radius : 10 x Cable diameter
Flame Retardant Test : IEC 332.1