Pair: 2 - 4
Cross-Section:
0,50 mm2 - 6 mm2
Cables | Silicone cables

SİMH - GL

Application

These silicone insulated cables are used as mobile connecting cables for equipment where high temperatures can arise as well as for ambient air temperature between 60 °C and +200 °C. These cables are used in all where installation conditions are very difficult and mechanical stress is high, e.g in ship building, power plants, cooking plants, glass and ceramic works, for high power lighting fixtures etc.

Cable design Tehnical data
Conductor    : Plain Cu wires, flexible acording to IEC 228-5.
Insulation : Silicone rubber compound.
Core identification : According to VDE 0293-308.
Lay-up : Cores laid up in layers of optimum pitch.
Outer Sheath : Silicone rubber compound.
Sheath Colour : Oxbrown-red
Braid : Glass fibre braid.
Standard : VDE 0250
Insulation resistance : > 20 Mohm.km    
Rated voltage Uo/U : 300 / 500 V
Test voltage (AC 50 Hz) : 2000 V
Temperature range : -60 °C / +200 °C
Min. Bending radius : 7,5 x Cable diameter
Flame test : IEC 332-1 & IEC 332-3