| Pair : 10 - 20 - 30 - 50 - 100 Cross-Section: 24 AWG |
Cables | Data cables |
| CATEGORY 3 TIA/EIA 568A | |
| Application: | |
These cables are used for transmission of analog and digital signals up to 16 Mbit/sec; at indoor applications. |
|
| Pair : 10 - 20 - 30 - 50 - 100 Cross-Section: 24 AWG |
CATEGORY 5 S-UTP/PE TIA/EIA 568-A |
| Application: | |
These cables are used for transmission of analog and digital signals up to 100 Mbit/sec; at outdoor applications. |
|
| Pair : 10 - 20 - 30 - 50 - 100 Cross-Section: 24 AWG |
CATEGORY 5E TIA/EIA 568-B.2 |
| Application: | |
These cables are used for transmission of analog and digital signals up to 155 Mbit/sec; at indoor applications. |
|
| Cable design | CAT 3 4 x 2 x 24 |
CAT 5S-UTP/PE 4 x 2 x 24 |
CAT 5E 4 x 2 x 24 |
| Inner conductor (mm) | Plain Cupper Ø 0,51 | Plain Cupper Ø 0,51 | Plain Cupper Ø 0,51 |
| Insulation (mm) | Solid PE veya PVC Ø 1,00 | Solid PE Ø 1,00 | Polyolefin Ø 1,00 |
| Drain wire | Ø 0,51 SnCu | ||
| Overall Screen braid coverage |
AL-PES Tape | ||
| Outer sheath (mm) | PVC, RAL7032, Gray Ø 5,50 |
PVC + POLYETHYLENE (PE) Ø 6,40 | PVC, RAL7032, Gray Ø 5,50 |
| AL-PES Tape: Aluminium polyester tape SnCu: Tinned Copper | |||
| Tehnical data | CAT 3 4 x 2 x 24 |
CAT 5S-UTP/PE 4 x 2 x 24 |
CAT 5E 4 x 2 x 24 |
| Impedance (1-100 MHz) | 100 ± 15 | 100 ± 15 | 100 ± 15 |
| Conductor resistance (20 °C) | Max. 94 Ohm / km | Max. 94 Ohm / km | Max. 94 Ohm / km |
| Insulation resistance | Min. 5 GOhm.km | Min. 5 GOhm.km | Min. 5 GOhm.km |
| Mutual Capacitance | Max. 56 nf / km | Max. 56 nf / km | Max. 56 nf / km |
| Operating Voltage | 250 V | 250 V | 250 V |
| Test voltage | 1200 V | 1200 V | 1200 V |
| Temperature range | -30 °C / +70 °C | -30 °C / +70 °C | -30 °C / +70 °C |
| Min. Bending radius | 5x Cable Diameter | 5x Cable Diameter | 5x Cable Diameter |
| CORE IDENTIFICATION COLOUR | ||
| Pair Number | a-Wire | b-Wire |
| 1 | Blue | White Blue |
| 2 | Orange | White Orange |
| 3 | Green | White Green |
| 4 | Brown | White Brown |
| ATTENUATION TABLE | |||||||||
| Frequency | Attenuation (dB/100m) | Near End Crosstalk NEXT (dB/100m) |
Struc. Return Loss (SRL) (dB) |
||||||
| (MHz) | CAT3 | CAT5 S-UTP | CAT5E | CAT3 | CAT5 S-UTP | CAT5E | CAT3 | CAT5 S-UTP | CAT5E |
| 1 | 2,6 | 2,1 | 2,0 | 41,0 | 62,0 | 62,0 | 12 | 23,0 | 23,0 |
| 4 | 5,6 | 4,3 | 4,1 | 32,0 | 53,0 | 53,0 | 12 | 23,0 | 23,0 |
| 10 | 9,7 | 6,6 | 6,5 | 26,0 | 47,0 | 47,0 | 12 | 23,0 | 23,0 |
| 16 | 13,1 | 8,2 | 8,2 | 23,0 | 44,0 | 44,0 | 10 | 23,0 | 23,0 |
| 20 | 9,2 | 9,2 | 42,0 | 42,0 | 23,0 | 23,0 | |||
| 31,25 | 11,8 | 11,7 | 40,0 | 40,0 | 21,0 | 21,0 | |||
| 62,5 | 17,1 | 17,1 | 35,0 | 39,0 | 18,0 | 18,0 | |||
| 100 | 22 | 22,0 | 32,0 | 38,0 | 16,0 | 16,0 | |||
| 155 | 25,3 | 37,0 | 14,0 | ||||||