Cables | Coaxial cables | ||||
Tip RG |
6 / U-4 | 6 / U-6 | 11 / U-4 | 11 / U-6 |
APPLICATION: 75 ohm cables used as connection cable in CATV, CCTV and satellite and common antenna TV systems. 50 ohm cables used as a connection cable in data transmission and radio communication systems |
CABLE CONSTRUCTION | ||||
Inner conductor (mm) | 1,0 Cu | 1,0 Cu | 1,63 Cu | 1,63 Cu |
Insulation (mm) | FPE, 4,70 | FPE, 4,70 | FPE, 7,30 | FPE, 7,30 |
Outer conductor | AL-PES | AL-PES | AL-PES | Cu-PES |
Braid | %60 SnCu | %60 Cu | %60 SnCu | %60 Cu |
Outer sheath | PVC White | PVC White | PVC Black/Red | PVC Black/Green |
Outer diameter (mm) | 7,00 | 7,00 | 10,30 | 10,50 |
TECHNICAL DATA | ||||
Impedance (Ohm) | 75 ± 3 | 75 ± 3 | 75 ± 3 | 75 ± 3 |
Velocity ratio (v/c) | 0,78 | 0,78 | 0,78 | 0,78 |
Capacitance(pF/km)800 Hz. | 57 | 57 | 57 | 57 |
Attenuation 100 MHz. 200 MHz. 400 MHz. 600 MHz. 800 MHz. |
(dB/100m) 7 9,7 14 17 20 |
(dB/100m) 6,5 9,5 14 17 20 |
(dB/100m) 4,6 6,7 9,8 13 15 |
(dB/100m) 4,6 6,7 9,8 13 14,4 |
Operating voltage Test voltage |
1,3 kV 3,0 kV |
1,3 kV 3,0 kV |
2,0 kV 5,0 kV |
2,0 kV 5,0 kV |
Min. Bending radius (mm) | 10xD | 10xD | 10xD | 10xD |
Temperature range | -40°C +70°C | -40°C +70°C | -40°C +70°C | -40°C +70°C |
PE FPE AL-PES Cu-PES |
: : : : |
Polyehtylene Foam Polyehtylene Aluminium Polyester Tape Copper coated polyester Tape |
Cu SnCu STW |
: : : |
Plain Copper Tinned Copper Steel Wire Braiding |