Tip RG | HALOGEN-FREE FLAME RETARDANT COAXIAL CABLES | |||
6 / U4 - HF | 6 / U6 - HF | 11 / U4 - HF | 11 / U6 - HF | |
APPLICATION: These cables are used as connection cable in CATV, CCTV and satellite and common antenna TV systems. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. |
![]() |
![]() |
![]() |
![]() |
CABLE CONSTRUCTOIN | ||||
Inner conductor (mm) | 1,0 Cu | 1,0 Cu | 1,63 Cu | 1,63 Cu |
Insulation (mm) | FPE, 4,70 | FPE, 4,70 | FPE, 7,30 | FPE, 7,30 |
Outer conductor | AL-PES | Cu-PES | AL-PES | Cu-PES |
Braid | %60 SnCu | %60 Cu | %60 SnCu | %60 Cu |
Outer sheath | HFFR, Black | HFFR, Black | HFFR, Black | HFFR, Black |
Outer diameter (mm) | 7,00 | 7,00 | 10,30 | 10,50 |
TECHNICAL DATA | ||||
Impedance (Ohm) | 75 ± 3 | 75 ± 3 | 75 ± 3 | 75 ± 3 |
Velocity ratio (v/c) | 0,78 | 0,78 | 0,78 | 0,78 |
Insulation resistance (Mohm.km) | > 2000 | > 2000 | > 2000 | > 2000 |
Capacitance (pF/km) 800 Hz. | 57 | 57 | 57 | 57 |
Attenuation 100 MHz. 200 MHz. 400 MHz. 600 MHz. 800 MHz. |
(dB/100m) 7 9,7 14 17 20 |
(dB/100m) 6,5 9,5 14 17 20 |
(dB/100m) 4,6 6,7 9,8 13 15 |
(dB/100m) 4,6 6,7 9,8 13 14,4 |
Flame test | IEC 332-1 IEC 332-3 |
IEC 332-1 IEC 332-3 |
IEC 332-1 IEC 332-3 |
IEC 332-1 IEC 332-3 |
Halogen-free test | IEC 754-2 | IEC 754-2 | IEC 754-2 | IEC 754-2 |
Smoke Density | IEC 1034 | IEC 1034 | IEC 1034 | IEC 1034 |
Operating voltage Test voltage |
1,3 kV 3,0 kV |
1,3 kV 3,0 kV |
2,0 kV 5,0 kV |
2,0 kV 5,0 kV |
Min. Bending Radius (mm) | 10xD | 10xD | 10xD | 10xD |
Temperature Range | -40°C +70°C | -40°C +70°C | -40°C +70°C | -40°C +70°C |
PE FPE AL-PES |
: : : |
Polyehtylene Foam Polyehtylene Aluminium Polyester Tape |
Cu-PES Cu SnCu |
: : : |
Copper coated polyester Tape Plain Copper Tinned Copper |