| Tip RG | UNDERGROUND TYPE PE SHEATED COAXIAL CABLES | |||
| 6 / U-4 P | 6 / U-6 P | 11 / U-4 P | 11 / U-6 P | |
| APPLICATION: These cables are used as connection cable in CATV, CCTV and satellite and common antenna TV systems for outdoor and underground distributions |
![]() |
![]() |
![]() |
![]() |
| CABLE CONSTRUCTOIN | ||||
| Inner conductor (mm) | 1,0 Cu | 1,0 Cu | 1,63 Cu | 1,63 Cu |
| Insulation (mm) | FPE, 4,70 | FPE, 4,70 | FPE, 7,30 | FPE, 7,30 |
| Outer conductor | AL-PES | Cu-PES | AL-PES | Cu-PES |
| Braid | %60 SnCu | %60 Cu | %60 SnCu | %60 Cu |
| Outer sheath | PE, Black | PE, Black | PE, Black | PE, Black |
| Outer diameter (mm) | 7,00 | 7,00 | 10,30 | 10,50 |
| TECHNICAL DATA | ||||
| Impedance (Ohm) | 75 ± 3 | 75 ± 3 | 75 ± 3 | 75 ± 3 |
| Velocity ratio (v/c) | 0,78 | 0,78 | 0,78 | 0,78 |
| Insulation resistance (Mohm.km) | > 2000 | > 2000 | > 2000 | > 2000 |
| Capacitance (pF/km) 800 Hz. | 57 | 57 | 57 | 57 |
| Attenuation 100 MHz. 200 MHz. 400 MHz. 600 MHz. 800 MHz. |
(dB/100m) 7 9,7 14 17 20 |
(dB/100m) 6,5 9,5 14 17 20 |
(dB/100m) 4,6 6,7 9,8 13 15 |
(dB/100m) 4,6 6,7 9,8 13 14,4 |
| Operating voltage Test voltage |
1,3 kV 3,0 kV |
1,3 kV 3,0 kV |
2,0 kV 5,0 kV |
2,0 kV 5,0 kV |
| Min. Bending Radius (mm) | 10xD | 10xD | 10xD | 10xD |
| Temperature Range | -40°C +70°C | -40°C +70°C | -40°C +70°C | -40°C +70°C |
| PE FPE AL-PES |
: : : |
Polyehtylene Foam Polyehtylene Aluminium Polyester Tape |
Cu-PES Cu SnCu |
: : : |
Copper coated polyester Tape Plain Copper Tinned Copper |